Installation & Setup Our Sites Site Links About Us Find Us Vista Forums Eight Forums Ten Forums Help Me Bake Network Status Contact Us Legal Privacy and cookies Windows 7 Forums Une erreur systme s'est produite. Seemingly narrowing the problem down to WMI not functioning correctly, I checked the computer's services to ensure that the Windows Management Instrumentation service was Started and set to automatic. Please try the request again.

Add comment Created on Oct 1, 2012 2:53:43 PM by Marcel Wiechmann (0) ●1 ●1 Permalink Votes:0 Your Vote: Up Down Having worked through a few of the suggested fixes above, Nevertheless to say, the same file is copied to your hard disk during Windows installation. USE AT OWN RISK! Add comment Created on Jun 17, 2010 3:06:18 AM by Major Weber (10) Permalink Votes:0 Your Vote: Up Down Thanks for this information, we've added it to the main article above.

Windows Could Not Start The Windows Management Instrumentation Service On Local Computer

To test WMI functionality further, I ran in the command prompt: wmic.exe computersystem get model. Just type a semi colon (;) at the end of the existing value and the new path specified: a) In case “Variable Value” textbox is empty, type below command: %SystemRoot%\system32;%SystemRoot%;%SystemRoot%\System32\wbem b) This can be viewed by running the following command from Start, Run: CMD /K SC QC WINMGMT The output should exactly as given below. [SC] GetServiceConfig SUCCESS SERVICE_NAME: winmgmt TYPE :

Generated Wed, 02 Nov 2016 22:13:04 GMT by s_wx1199 (squid/3.5.20) {{offlineMessage}} Store Store home Devices Microsoft Surface PCs & tablets Xbox Virtual reality Accessories Windows phone Software Office Windows Additional software Click Start, Run and type Regedit.exe Navigate to the following location HKEY_LOCAL_MACHINE \ SYSTEM \ CurrentControlSet \ Services\ winmgmt Double-click DependOnService and set it's Value data to RPCSS Close Regedit and My System Specs Computer type Laptop System Manufacturer/Model Number Asus K52F or Lenovo B80 OS Win 7 x64 Home Premium (and x86 VirtualBox VM)/Win10 CPU i3 370M/i7 6500U Motherboard Asus/Lenovo Memory Trustedinstaller Error 2 Open a command prompt window (Run as Administrator) Enter the following command: net stop winmgmt With a Windows Explorer rename the directory %windir%\System32\wbem\repository on a 32bit Windows to %windir%\System32\wbem\repository_old (or %windir%\SysWOW64\wbem\repostiory

This compilation is gathered from many resources, mainly Microsoft web sites. Error 126 The Specified Module Could Not Be Found Looking at the script, it was where a WMI method was being invoked to install the driver. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy • https://www.404techsupport.com/2012/11/wmi-commands-result-in-the-specified-module-could-not-be-found/ On older Windows systems up to 2003 you have to clear earlier resnyc attempts (on newer systems this will not work): winmgmt /clearadap 3.

NOTE: Working with the registry is for advanced users only. The Windows Modules Installer Service Terminated With The Following Error: 7023 You are invited to get involved by asking and answering questions! Type for /f %s in (‘dir /b *.dll') do regsvr32 /s %s and press Enter to re-register WMI DLL files. 5. Copyright ©2016 · 404TechSupport.com Send to Email Address Your Name Your Email Address Cancel Post was not sent - check your email addresses!

Error 126 The Specified Module Could Not Be Found

The system returned: (22) Invalid argument The remote host or network may be down. http://www.sevenforums.com/windows-updates-activation/305140-error-126-cannot-start-service-windows-modules-installer.html hr = 0x80070005, Accs refus. . Windows Could Not Start The Windows Management Instrumentation Service On Local Computer I'll start a different thread if I can't manage to fix that myself after reading the abundant literature on the topic. Windows Could Not Start The Trustedinstaller Service On Local Computer Error 2 Unregister and reregister the DLL file as shown below: For Windows 8.1/ 8 and Earlier Versions: Open Command Prompt as mentioned in “Copy missing file from installation disc” paragraph Type the

So those "read & execute" permissions look normal - is that error 126 due to something else then? It gave a line number in the script and an error message of "The specified module could not be found". USE AT YOUR OWN RISK! To remove the additional Dependencies, follow this: WARNING: If you use Registry Editor incorrectly, you may cause serious problems that may require you to reinstall your operating system. Windows Could Not Start The Trustedinstaller Service Error 2

  1. The time now is 17:17.
  2. This might help with WMI problems.
  3. The last step is ICACLS command saying "c:\windows\CSC\trustedinstaller.*: Access Denied" ...
  4. Kn0wing this, the technician included me in the troubleshooting process to see if there was something wrong with the script or some other configuration.
  5. However, as it is very complex and based on a complex communications protocol (DCOM) it tends to be more error-prone than everyone would like it to be.
  6. The restart management services option If you encounter problems with non-existing counters after installing/restarting software products or virtual machines, a restart of the WMI services might help (example service names shown

Step 1 Download RegInOut, Scan for Windows Issues Your System: Windows, English? Anything else I should try? As PRTG uses the WMI systems on both sides of a connection you have these two options: Rebooting the PRTG probe computer If many/all host computers show inexplicable WMI errors, the When I right clicked on the service and clicked on Start , I am getting a pop-up with the...

Add comment Created on Dec 2, 2014 7:28:49 PM by dbreit (0) Permalink Please log in or register to enter your reply. Error 126 The Specified Module Could Not Be Found Python Many thanks, Thierry Code: C:\Windows\system32>sc stop vss SERVICE_NAME: vss TYPE : 10 WIN32_OWN_PROCESS STATE : 3 STOP_PENDING (STOPPABLE, NOT_PAUSABLE, ACCEPTS_SHUTDOWN) WIN32_EXIT_CODE : 0 (0x0) SERVICE_EXIT_CODE : 0 (0x0) CHECKPOINT : 0x0 Share this:FacebookTwitterRedditGoogleEmailPrint Related Filed Under: Tech SolutionsFollow Us  Subscribe to 404TS articles by email.

The recompile MOFs option All WMI counters are defined in text files, the so called MOFs.

The processor and Installed Memory fields were returning ‘not available'. In that case you’ll have to reinstall the whole product to get your problem solved. errors fix kaputt last-resort prtg troubleshooting wmi Created on Apr 12, 2010 12:14:29 PM by Volker Uffelmann [Paessler Support] Last change on Jun 10, 2010 1:36:07 PM by Volker Uffelmann [Paessler System Error 126 Odbc For Windows 8.1/ 8 and Earlier Versions: Press Windows Key + R Type “Services.msc” and click OK Scroll down, locate and right click “Windows Defender” and select Properties Under General tab

The WMI diag option A very good start to approaching WMI problems is the use of Microsoft's very own diagnosis tool, WMIDiag, of course. Votes:0 Your Vote: Up Down My WMI sensors keep returning with errors that should not occur. It is now reporting correct disk space utilization. Understanding PRTG's use of WMI for monitoring Windows computers First of all you should be aware that PRTG uses high-level Windows-functions for accessing WMI - so very often an error is