Home > Event Id > Windows 7 Error Event Id 2017

Windows 7 Error Event Id 2017

Contents

XP workstations after a period of time are disconnected to Windows 7 shares. Errors on the Windows 7 system logs occur at the same time as the problem. To remove the fix and re-enabled SMB2 simply remove the DWORD from the place above in the registry. Most tuning parameters are inaccessible, but a few are located in the Registry. More about the author

Any suggestions? Right click computer and click manage. Solved Nonpaged pool limit - System Error in Win7? By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks. https://social.technet.microsoft.com/Forums/office/en-US/30919e4f-6810-48d6-8769-2cff61f07544/event-id-2017-the-server-was-unable-to-allocate-from-the-system-nonpaged-pool-because-the-server?forum=w7itpronetworking

Event Id 2017 Unable To Collect Numa Physical Memory Utilization Data

newsgator Bloglines iNezha Search for: Recent Posts RHEL / CnetOS 7 sftp logging in chroot Midnight Commander UTF8 line drawing characters problem iFive Mini3 gets ANDROID 4.4 firmware How-To disable IPv6 Email check failed, please try again Sorry, your blog cannot share posts by email. %d bloggers like this: Home Getting event 2017 LanmanServer on a Windows 7 64 PC by Jim Want to Advertise Here? Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password?

  1. With everyone logged in, the computer is using between 2 and 3 GB.  Page file is automatically managed, but is at 12g.
  2. Friday, March 08, 2013 9:38 PM Reply | Quote 1 Sign in to vote krbaugh, thank you so much!
  3. WSUS Windows 7 Windows 8 Windows Server 2012 Windows Server 2008 Appearance and Personalization on Windows 7 Video by: Faizan This Micro Tutorial will teach you how to change your appearance
  4. I will post if that error comes back or I get disconnected to access that mapped drive.
  5. Join the community Back I agree Powerful tools you need, all for free.
  6. Just in case that page goes away for some reason I've copied some of the information here for my own and perhaps others use.

The very first entry has a weird name it's like _76582#_38943 some junk like that. Only Go to Solution 13 Comments LVL 22 Overall: Level 22 Windows 7 17 Windows OS 6 Operating Systems 1 Message Expert Comment by:senad2010-01-10 One user's experience : Apparently you The system returned: (22) Invalid argument The remote host or network may be down. Hklm\system\currentcontrolset\control\session Manager\memory Management\largesystemcache The various selections actually change the values of two Registry values:

HKLMSYSTEMCurrentControlSetControlSession ManagerMemory ManagementLargeSystemCache and HKLMSYSTEMCurrentControlSetServicesLanmanServerParametersSize This table (which was derived from sessions with ‘Regmon' (http://technet.microsoft.com/en-us/sysinternals/bb896652.aspx)) presents the settings you should

Latest Technology PodCast Episode 17 - Canadian Anti-Spam Legislation (CASL) Morgan Report Special Offer CTOBOB Twitter Feed Tweets by @ctobob CTOBOB Technology Podcast Available Now! Event Id 2017 Numa Disabling it and forcing SMB1 (pre vista networking) fixes the problem and finally all my machines are able to connect to the Vista shares even after days of use. This computer is used as a file server and is constantly accessed day in day out. see it here Polls Archive Recent Posts New Intel® Solid State Drive Toolbox version 3.3.7 released!

Designed by Screemer. Alan Lamielle Net 2009 Windows Nonpaged Pool Srv Error 2017 All rights reserved. Some research led me to find this Google Groups discussion about the problem and this Microsoft Technet article discussing the solution (look at the bottom of the page). Monday, July 25, 2016 6:12 PM Reply | Quote 0 Sign in to vote Thank you krbaugh for your contribution.

Event Id 2017 Numa

I found a simple solution after a bit of research. http://ctobob.com/2013/12/14/microsoft-windows-7-share-causes-issues-event-id-2017-error/ Login here! Event Id 2017 Unable To Collect Numa Physical Memory Utilization Data The author and this site is not responsible for any damages for the use of highlighted products or solutions. (C) 2013 CTOBOB.com Admired Theme MenuExperts Exchange Browse BackBrowse Topics Open Questions Id Festival 2017 Tuesday, August 06, 2013 11:05 PM Reply | Quote 2 Sign in to vote thank you, excelent....helpful and concise! :) Thursday, August 08, 2013 5:50 PM Reply | Quote 1 Sign

All rights reserved.Newsletter|Contact Us|Privacy Statement|Terms of Use|Trademarks|Site Feedback TechNet Products IT Resources Downloads Training Support Products Windows Windows Server System Center Browser   Office Office 365 Exchange Server   SQL Server http://pdctoday.com/event-id/windows-error-event-id-10.php They reboot to clear the issue, and some days they have reported having the issue several times in the same day, other times it can go a few days. 0 This Covered by US Patent. Thanks in advance for any advice -Jim Event log error: Log Name:      System Source:        srv Date:          11/8/2013 2:20:54 PM Event ID:      2017 Task Category: None Level:         Error Keywords:      Classic User:          N/A Event Id 2017 Source Perfos

Join the community of 500,000 technology professionals and ask your questions. This is a registry value under HKLM\System\CurrentControlSet\Services\LanManServer\Parameters. By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks. click site Generated Wed, 02 Nov 2016 13:44:57 GMT by s_fl369 (squid/3.5.20) home| search| account| evlog| eventreader| it admin tasks| tcp/ip ports| documents | contributors| about us Event ID/Source search Event

That impact is more serious. Windows Server 2012 R2 Event Id 2017 First Name Please enter a first name Last Name Please enter a last name Email We will never share this with anyone. Then click createkey and create a DWORD with the name SMB2.

This change along with the LargeSystemCache setting stopped my disconnect issue and the error messages. 0 LVL 16 Overall: Level 16 Windows 7 2 Windows OS 1 Message Author Comment

The closest information I found was for Server 2008. By creating an account, you're agreeing to our Terms of Use and our Privacy Policy Not a member? Bottom line: Try it. Srv 2017 This was extremely helpful for resolving my network scanning issue.

No trackbacks yet. It appears that Vista uses SMB2 for networking and its obviously buggy in certain circumstances. Join the community Back I agree Powerful tools you need, all for free. navigate to this website What are some clever ways to clean a laptop keyboard?

I solved this by changing registry settings: Changed: HKLM\SYSTEM\CurrentControlSet\Control\Session Manager\Memory Management\LargeSystemCache - Set it to 1(was 0) Changed: HKLM\SYSTEM\CurrentControlSet\Services\LanmanServer\Parameters\Size - Set it to 3(was 1) See Also ME232271. Fixed! Every day or two they get the 2017 error, i will post the full error at the bottom. This is a direct quote from that page so if Alan doesn't like it please contact me and I will remove it ASAP!

However, only available memory can be used for caching. Posted on 2010-01-09 Windows 7 Operating Systems Windows OS 2 Verified Solutions 14 Comments 6,320 Views Last Modified: 2012-08-14 I have Windows 7 64-bit, and found three of the following errors Luckily I decided instead to just look through the event viewer, and I found this very Event ID at times that I knew the xp machines had been kicked out of Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password?

If you increase the file cache allocation units, you will experience a slow-down of applications, so you should be careful about settings. 0 LVL 1 Overall: Level 1 Windows OS Custom search for *****: Google - Bing - Microsoft - Yahoo Feedback: Send comments or solutions - Notify me when updated Printer friendly Subscribe Subscribe to EventID.Net now!Already a subscriber? Thank you for posting this five years ago. This is not to be mistaken for a disconnected drive!The client is desperately attempting to reach the drive, which it believes to still be their.

See example of private comment Links: EventID 2017 from source NCP Server Search: Google - Bing - Microsoft - Yahoo - EventID.Net Queue (0) - More links...