Home > Winsock Error > Winsock Connect Error System Error 10038

Winsock Connect Error System Error 10038

Contents

WSAENOBUFS 10055 No buffer space available. For information, see the Handling Winsock Errors topic. Now select the Mirror Driver Tab (not the Display Options Tab), and then enable Force 8-bit display setting, and set Compression to 9 (Maximum). In order for the license manager to work with network security software and firewalls, you must specify an open port on your system for MLM. my review here

blackwc Guest Re: Winsock Error Code: 10038 « Reply #5 on: May 08, 2007, 06:12:20 PM » Sure, no problem...Here the WM_SOCKET message in the main dialog procCode: .elseif eax == The connection has been broken due to keep-alive activity detecting a failure while the operation was in progress. An operation was attempted on a nonblocking socket with an operation already in progress—that is, calling connect a second time on a nonblocking socket that is already connecting, or canceling an So simply blocking inbound / outbound traffic by port isn't really the correct thing to do when you're working with Client/Server type TCP applications, and if this were the case I http://forums.dameware.com/viewtopic.php?f=9&t=542

Winsock Errors

The WSAGetLastError function returns the last error that occurred for the calling thread. Not the answer you're looking for? A database query failed because it was actively refused. Applications that use WSAGetOverlappedResult (with the fWait flag set to FALSE) in a polling mode to determine when an overlapped operation has completed, get this error code until the operation is

  • If they do match, make sure the port is valid and not in use by another application.
  • WSAENETRESET (10052) Net dropped connection or reset The host you were connected to crashed and rebooted.
  • Typically, only one usage of each socket address (protocol/IP address/port) is permitted.
  • A server has attempted to handle an NFS request by generating a request to another NFS server, which is not allowed.WSAHOST_NOT_FOUND (11001) Host not found The name you have used is
  • P.S.
  • A system call that should never fail has failed.

The application has tried to determine the status of an overlapped operation which is not yet completed. Return code/valueDescription WSA_INVALID_HANDLE 6 Specified event object handle is invalid. An example is using a broadcast address for sendto without broadcast permission being set using setsockopt(SO_BROADCAST). Winsock Reset a second time (or subsequent) on a non-blocking socket.WSAENOTSOCK (10038) Socket operation on non-socket An operation was attempted on something that is not a socket.

A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond. Winsock Error 10061 If nothing is listening on this specified port (i.e. Note: this error may also result if you try to send a multicast packet and the default gateway does not support multicast (check your interface configuration). https://msdn.microsoft.com/en-us/library/windows/desktop/ms740668(v=vs.85).aspx Linked 1 Indy error 10038 “Socket operation on non-socket” after 61 seconds of inactivity -3 Winapi: use select on pipe returns 10038 Related 1Bind Error 10038 with windows socket application in

c++ winsock share|improve this question asked Apr 14 '14 at 21:18 Dries 375116 WSAENOTSOCK. What Is My Ip You should simply ignore this error when it occurs.WSAEINTR (10004) Interrupted system call A blocking operation was interrupted by a call to WSACancelBlockingCall. Once open, you should be able to check out a license through a firewall.NOTE: If client machines have a firewall, you will need to open the two ports on the client In this case, the WSAEBADF error might mean the same as a WSAENOTSOCK error.

Winsock Error 10061

By default, it's currently set to Socket Logon Timeout=90000 (in milliseconds), so you can try doubling that value to start out. click for more info Blocking on outbound connections is not typically done in Firewalls because then basically nothing would work. Winsock Errors The following list describes the possible error codes returned by the WSAGetLastError function. Winsock Error 10060 Pairable strings Test if the value of a counter belongs to a given list of values Can Fireballs be saved for later in the Bag of Holding?

A retry at some time later may be successful. http://pdctoday.com/winsock-error/winsock-error-in-of-connect.php more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed As it is part of Windows since Win98 (and downloadable for Win95), I'd recommend using at least winsock2. When a particular Windows Sockets function indicates an error has occurred, this function should be called immediately to retrieve the extended error code for the failing function call. Socket Error 10060

Winsock description: The Windows Sockets definition of this error is very different from Berkeley Sockets. This error occurs if an application passes an invalid pointer value, or if the length of the buffer is too small. An overlapped operation was canceled due to the closure of the socket, or the execution of the SIO_FLUSH command in WSAIoctl. get redirected here System Error: 10038 "Winsock: Specified socket is invalid"or FLEXlm error: -15,570.

I have the server running by the way. –Dries Apr 14 '14 at 21:27 WSAECONNREFUSED: Usually one of following: a) There is no server program at the specified port. NOT LIKE and LIKE not returning opposite result Secret Reception What are these aircraft seen in this aerial photo? This is usually caused by one or more of the function pointers being NULL.

An existing connection was forcibly closed by the remote host.

WSAEINVAL 10022 Invalid argument. Not the answer you're looking for? All Rights Reserved. The New Apprentice What is the first text considered Italian instead of Latin?

Check that no old Windows Sockets DLL files are being accessed. The Mini Remote Control program will first attempt a straight TCP connection to the remote machine, using the Port that you specified for communication. Does it make sense for these space ships to have turrets? http://pdctoday.com/winsock-error/winsock-connect-error.php TCP/IP scenario: A connection will timeout if the local system doesn't receive an (ACK)nowledgement for data sent.

Errors are listed in numerical order with the error macro name. Do dictionaries that don't exist online reflect current usage? also whats the difference between winsock and winsock2? WSA_QOS_EPSFLOWSPEC 11027 Invalid QoS provider-specific flowspec.

Therefore, you may also want to try selecting this Host Entry, and then click on the Settings button. Note that the v1.1 Winsock specification does not explicitly state that this error occurs if the value you request is larger than the WSAData.iMaxUdpDg returned from WSAStartup. The requested name is valid and was found in the database, but it does not have the correct associated data being resolved for. This usually results from trying to connect to a service that is inactive on the foreign host.