Home > Winsock Error > Winsock Error Connection Refused Server Probably Not Running

Winsock Error Connection Refused Server Probably Not Running

We'll email youwhen relevant content isadded and updated. Try login to the client after this, it should be working. I am trying to get the property information of documents in a DocBase. Re: DM_DOCBROKER_E_NETWORK_ERROR Babu03 Nov 15, 2005 8:19 AM (in response to Erin Riley) No File or directory ...when i did just ls i get thiscompat cv2 .........anaconda-ks.cfg.....No idea whats going on his comment is here

check thisand try again._______________________________________________Robin EastXense - Documentum Performance Consultinghttp://www.xense.co.ukPost by gokul_rajHi All,I tried to Install Desktop Client in Windows 2000 Prof , SP 4.I am getting the following error while connecting Is it possible to connect to the RDBMS that documentum uses for this purpose ? For more information, please refer to the FLEXlm End User Guide, version 9, section B.1.3 (the document, enduser.pdf, can be found in the Utilities/FLEXlm directory of your ARM RealView tools CD-ROM). History Contributors Ordered by most recent Michael Tidmarsh49,325 pts. 0101730125 pts.

An extension to your real life group of friends, interests and communities. Report Abuse Like Show 0 Likes (0) 1 2 3 Previous Next Go to original post Actions More Like This Retrieving data ... Groups is subject to: http://docs.yahoo.com/info/terms/ <> Previous Message by Thread: RE: local host connects, all remote machines do not, CANT_CONNECT error I had the same problem in one of my projects. Privacy Reply Processing your reply...

  1. Network address: (INET_ADDR: family: 2, port: 1489, host: thor.norsistemas.es (194.140.66.211, c28c42d3)). 09/27/00 13:18:13, Error 256The Docbroker request failed. 09/27/00 13:18:13, Error [email protected]:: THREAD: main; MSG: [DM_DOCBROKER_E_NETWORK_ERROR]error: "An error occured
  2. You will be sent to docbase configuration screen...just exit it. > > Try login to the client after this, it should be working. > > Sandeep. > > -----Original Message----- >
  3. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States.
  4. Report Abuse Like Show 0 Likes (0) Go to original post Actions More Like This Retrieving data ...
  5. Do you have a firewall?
  6. Firewall is disabled.
  7. Log in to post comments shamla-puthuparambil-sayid (Intel) Fri, 08/28/2009 - 08:59 Quoting - christophe.ogniervsg3d.com Hi,I have bought some licenses for Treadchecker, ThreadProfile, VTUne to run with the flexlm manager.Theses licenses are
  8. Thanks, Steven --- In [email protected], "Sandeep Singh" wrote: > I had the same problem in one of my projects.

Check out IPSec setting if you still face problem. Network specific error: (Winsock error: connection refused; server probably not running)." [DM_DOCBROKER_E_CONNECT_FAILED]error: "Unable to connect to DocBroker. We'll let you know when a new response is added. If it is named instance, on your target server machine, go to “SQL Server Configuration Manager”, open “Protocols for MSSQL$“, check TCP enabled, and right click TCP, find out the tcp

Through linux i got the ifconfig address and set the host in dmcl.ini , And started the tomcat App server, but iam getting the error posted above , i am not Server please check your server.ini or target attributes in server config. If so, hoping the commands are the same for unix, you can do a ps -ef to see what processes are running. http://osdir.com/ml/cms.documentum.user/2005-01/msg00078.html If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States.

The docbaseEMEA_DOC2 on server chnsh132031 is probably not running. Not a member? Clients please check your dmcl.ini file for a correct host. Thank YouShamla Hello,Thank you for your help.Even if non very convenient since it's a manual workaround, but I'm wondering if it's related to windows or flex ?I tried to edit the

Following Follow WSAECONNREFUSED When I open SAP, an error is displayed on the screen and says comment connection refused. navigate to this website The service cannot start. Don’t miss out on this exclusive content! Applied all Customizations and everything was working great for a month.

Then..you will be prompted for User ID and Password of the docbase...after you provide the same. this content The workaround for this problem...which is very silly... Register Hereor login if you are already a member E-mail User Name Password Forgot Password? Suddenly none of the clients such as Webtop, Application Builder, Application Installer were able to connect to Docbase from any machine.

Report Abuse Like Show 0 Likes (0) 14. Then on your client machine, do ” telnet “, see whether it succeeds. 6. You will be sent to docbase configuration > screen...just exit it. > > > > Try login to the client after this, it should be working. > > > > Sandeep. weblink You can not post a blank message.

b. All rights reserved. Please note that ARM does not support the use of WAN-based license.

Thanks, Steven --- In [email protected], "Sandeep Singh" wrote: > I had the same problem in one of my projects.

On Solaris or Linux, the equivalent system error message is "Connection refused". Here is my lic file (combined keys). Server please check your server.ini or target attributes in server config. Re: DM_DOCBROKER_E_NETWORK_ERROR Daniel Bularzik Nov 15, 2005 7:43 AM (in response to Babu03) From your linux partition:* Ensure you are connected as the documentum administrator (probably dmadmin)* Determine if your docbroker

Network problems.Please contact your System Administrator to resolve this problem. 09/27/00 13:18:13, File d:\vss\Desktop Client\Integrations\Windows Explorer\DcFolder\DcDocbasesFolder.cpp, Line 405An error occured performing a network operation: (Unknown error code 112 (_nl_error_ = Thanks for your help.. http://software.intel.com/en-us/articles/installing-license-server-on-vi... check over here I have verified that the CS is running fine without any issues.

Go to Documentum Server Manager, and try to click on the utilities and under the utlities tab, click on server configuration. DfDocbaseUnreachableException:: THREAD: main; MSG: [DM_SESSION_E_CANT_CONNECT]error: "Could not connect to docbase at host (dctmsvr) because (Winsock error: connection refused; server probably not running). Network address: (INET_ADDR: family: 512, > port: 10000, host: ABC (1.1.1.1, 921b08e2))." [DM_SESSION_E_AUTH_FAIL] > error: "Authentication failed for user exuser with docbase XYZ." > > > Thanks, > Steven Stuart > Does your target SQL instance enabled TCP and listening on a valid TCP port?

So tried Installing App Builedr on the E-Content Server and App Builder is able to connect locally but not through any other machines outside. The license server name is too long There is a character limit on host names imposed by the FLEXlm licensing software.If the license server's hostname is longer than the limit, you You will be sent to docbase configuration screen...just exit it. > > Try login to the client after this, it should be working. > > Sandeep. > > -----Original Message----- > By submitting you agree to receive email from TechTarget and its partners.

Request you to kindly send your resume and refer all your friends who might be interested. Following Follow Winsock error Thanks! The service cannot start. Register Hereor login if you are already a member E-mail User Name Password Forgot Password?

Get Access Questions & Answers ? Re: DM_DOCBROKER_E_NETWORK_ERROR Babu03 Nov 15, 2005 10:07 AM (in response to Babu03) Iam looking thru the link you have sent me but if i dnt see the $DOCUMENTUM/dba/log ... Firewalls Another cause of the problem is if the license server and client are on opposite sides of a firewall. Is the $DOCUMENTUM/dba/config directory there?

This usually results from trying to connect to a service that is inactive on the foreign host—that is, one with no server application running. Network address: (INET_ADDR: family: 512, port: 10000, host: ABC (1.1.1.1, 921b08e2))." [DM_SESSION_E_CANT_CONNECT]error: "Could not connect to docbase (XYZ) at host (ABC) because (Winsock error: connection refused; server probably not running). System Error: 10061 "WinSock: Connection refused"For further information, refer to the FLEXlm End User Manual,available at "www.macrovision.com". Report Abuse Like Show 0 Likes (0) 4.

Ask a question, help others, and get answers from the community Discussions Start a thread and discuss today's topics with top experts Blogs Read the latest tech blogs written by experienced