Home > Wmi Error > Wmi 13 Error

Wmi 13 Error

Contents

This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general. Option Explicit Dim WmiQuery WmiQuery = "SELECT * FROM Win32_Processor" Dim objSWbemLocator Set objSWbemLocator = CreateObject("WbemScripting.SWbemLocator") Dim objWMIService Set objWMIService = objSWbemLocator.ConnectServer("localhost", "root\cimv2") Dim results Set results = objWMIService.ExecQuery (WmiQuery) Dim WMI is therefore requested to retry the operation with simpler parameters. WBEM_E_MISSING_PARAMETER_ID 2147749942 (0x80041036) Parameter was missing from the method call. WBEM_E_INVALID_PARAMETER_ID 2147749943 (0x80041037) Method parameter has an ID Instead, problems connecting to a remote computer typically revolve around one of the following scenarios:The remote computer is not online.

Click the [Default] COM Security tab. If you do not, access to that computer will be denied. Before doing so you should enable WMI’s verbose logging option. Can WMI actually be "reinstalled" in Windows7 as it could in Windows XP via .INF? 3 years ago Reply Mr Yusufu the first part (script) worked the magic… i didn't even https://msdn.microsoft.com/en-us/library/aa394559(v=vs.85).aspx

What Is Wmi Error

Well, consider the following script, which returns the name of each tape drive installed on a computer: Copy strComputer = "." Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2") Set colItems If so, you might need to recompile the MOF file for the namespace in question; for more information on recompiling MOF files see I’m getting an error regarding provider registration. A WMI infrastructure problem, such as incorrect CIM or DCOM registration. 0x8007xxxx Errors originating in the core operating system. somewhere in "C:Program Files" (which is actually the case on my system).

This document (developed in conjunction with the WMI team at Microsoft) is designed to help you troubleshoot problems with WMI scripts and the WMI service. Although the Scriptomatic utility was designed as a way to help you write simple WMI scripts, the tool can also be used to diagnose problems with the WMI service.After downloading and If you are getting a “Remote server machine does not exist or is unavailable” error the first thing you should do is verify that the computer is actually online; you can Wmi Diagnosis Utility We encountered no state data under it we saw that the status shows that no state data.

Will the very fabric of space and time be ripped apart? Wmi Error Windows 7 The user must use a blank username/password and rely on default security. WBEM_E_CANNOT_BE_ABSTRACT 2147749989 (0x80041065) Class was made abstract when its parent class is not abstract. WBEM_E_AMENDED_OBJECT 2147749990 (0x80041066) However, you can add and edit your own mof. 47 years ago Reply Anonymous I think it is important to clarify and remember that when running in commandline, use for /f http://answers.microsoft.com/en-us/windows/forum/windows_7-performance/wmi-error-under-event-viewer-with-error-code/aee1e6c9-28d5-4871-908b-8ed42a36a96e To enable verbose logging using the WMI control, do the following:Open the Computer Management MMC snap-in and expand Services and Applications.Right-click WMI Control and click Properties.In the WMI Control Properties dialog

The topics in this document are listed roughly in order; for example, the last thing you should do is rebuild the entire Repository. Rebuild Wmi Repository http://www.microsoft.com/…/details.aspx Supported Operating Systems: Windows 7, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Vista, Windows XP 7 years ago Reply Joe Diggs How do you change WMI In that case, you might try this script, which attempts to bind to the Win32_Process class: Copy strComputer = "." Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2:Win32_Process") If this script The Application's debug log files looklike the following: DEBUG LOGS FROM COMPONENT TEST --------------------------------------------------------- 2016-06-03 13:26:24,503 [STP SmartThreadPool Thread #1] [C938] DEBUG SolarWinds.APM.Probes.WMI.WMIHelper - Trying to connect to '127.0.0.1' as ''

  1. For example, the command net helpmsg 64 returns the message: The specified network name is no longer available.
  2. Key in dictionary: 'period' Key being added: 'period.'Error: Server and Application Monitor requires SQL 2008 or higherError: Server Error in '/' Application when accessing the console after upgrading SAMError: Setup is
  3. Provider failed to export DllRegisterServer.
  4. It is possible that the class definitions currently in the Repository have somehow become corrupted; in that case, recompiling your .MOF files will cause those class definitions to be overwritten and

Wmi Error Windows 7

Path: HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System Add a new DWORD value: Name: LocalAccountTokenFilterPolicy Value: 1 Note: This disables some of the protection provided by UAC. Continued Ensure that Enable “Distributed COM on this computer” is enabled Default Authentication Level is set to Connect Default Impersonation Level is set to Identify Assuming that DCOM is enabled, we also What Is Wmi Error Error number 0x80041013 means that “COM cannot locate a provider referenced in the schema;” error number 0x80041014 means that a component (such as a WMI provider) “failed to initialize for internal Wmi Error 10 If I put it in a batch it works. 10 months ago Reply Tim @Ryan: Thx, perfect work, this batch is smoothy 🙂 Pingback: LocTeam © 2016 Microsoft Corporation.

Click the [Default] COM Security tab. By default, many firewalls block DCOM and RPC traffic; if your firewall is blocking these protocols then your script will fail. In-process provider was not registered using the regsvr32 command. Microsoft Customer Support Microsoft Community Forums United States (English) Sign in Home Library Wiki Learn Gallery Downloads Support Forums Blogs We’re sorry. Wmi Error 0x80041003

Out-of-process provider was not registered using the /regserver switch. What do you think will happen? Any suggestions other than performing an in-place "upgrade" repair reinstallation of the entire OS? Unfortunately, not all versions of WMI are created equal.

Is something not registered in WMI or something? Wmi Error Codes You can use the following script by saving to txt file then renaming to .bat and running from command prompt with admin right and changing focus to following directory: C:\Windows\System32\Wbem. @echo Learning resources Microsoft Virtual Academy Channel 9 MSDN Magazine Community Forums Blogs Codeplex Support Self support Programs BizSpark (for startups) Microsoft Imagine (for students) United States (English) Newsletter Privacy & cookies

Dev centers Windows Office Visual Studio Microsoft Azure More...

Thanks The 1st script stopped WMIprvSE.exe using a lot of CPU on a a vista machine. 2 years ago Reply Addition to the above script... If you are running Windows XP or Windows Server 2003 (and assuming you have the appropriate Administrator rights and have your firewalls configured properly), you should be able to connect to Specifically, any remote access to the server using an administrator security token is automatically elevated with full administrator rights, including access to the root folder. Wmi Repository Verification Failed Contact the Domain Administrator to get this computer added to the Windows Authorization Access Group. WBEM_E_RETRY_LATER 2147758081 (0x80043001) Reserved for future use. WBEM_E_RESOURCE_CONTENTION 2147758082 (0x80043002) Reserved for future use.

The Win32_UserAccount class is also found on Windows 2000; however, the version of WMI installed on Windows 2000 does not include the LocalAccount property. Just wonder if you could take a look at my post on forum social.msdn.microsoft.com/…/4161d6a1-1b52-4aa9-98b9-eacad5ba2a90. Learn more about Private Packages and Organizations… how? In that case, try stopping and restarting the WMI service (see I’ve verified that the namespace, class, and property names are correct, yet my script still doesn’t work) and then proceed

If you suspect WMI or repository corruption, rebuilding repository is the last thing you should do. Private packages for the whole team It’s never been easier to manage developer teams with varying permissions and multiple projects. To resolve WMI issues, first make sure you have the latest WMI hotfixes, then run the commands associated with "winmgmt.exe". 47 years ago Reply Anonymous Last spring (2013), I wrote a That’s to be expected: after all, the script can’t return the names of the tape drives installed on the computer if there aren’t any tape drives installed on the computer.One way

Often-times script writers connect to the root\cimv2 namespace and then try to access the StdRegProv class. Most likely you will never even know that the service had been stopped. As I have said, it works for everything I've tried it with except PRTG. As a result, it will automatically rebuild the Repository the next time it needs to access WMI information.Restart the WMI service (net start winmgmt) and try your script again.If your script

Your cache administrator is webmaster.