From there, type the following at the command prompt and then press ENTER: Copy for %i in (*.dll) do RegSvr32 -s %i After the .DLLs have been re-registered you will then In fact, if you know which error message is being generated by your script or if your problem seems to fit one of the more-common scenarios, then you can jump directly Click the [Default] COM Security tab. Also, use the WMI Control to verify that permissions have been correctly set on the WMI namespaces before you resort to rebuilding the Repository.Windows Server 2003, Service Pack 1If you are

As I mentioned earlier, providers are represented as COM objects. Here are two resources: Script written by a Spiceworks user TechNet blog article detailing how to do this yourself through the command prompt WMI Diagnostic & Repair Tool If you are At that point click the drop-down list labeled WMI Namespace:This drop-down list shows all of the WMI namespaces found on the computer, making it easy for you to verify that: 1) Failures can originate in other parts of the operating system and emerge as errors through WMI.Never delete the WMI repository as a firsttroubleshooting stepbecause deleting the repository can cause damage to https://msdn.microsoft.com/en-us/library/aa394603(v=vs.85).aspx

Wmi Error Fix

Make sure that the Default Access Permissions lists the following accounts: Operating system Account Access Windows 2000 SELF Windows XP / Windows Server 2003 SELF Local and Remote Windows Vista / Give the user you want remote access, remote launch, and remote activation. You’ll be auto redirected in 1 second. Another issue I recently worked on involved applying GPOs.

  1. You are invited to get involved by asking and answering questions!
  2. For example, the WMI Repository is primarily a storehouse for meta-information about WMI itself.
  3. WMI Diagnosis Utility TOC Collapse the table of content Expand the table of content This documentation is archived and is not being maintained.
  4. WMI repository corruption may masquerade as classes or instances "not found".
  5. You can find additional information about setting WMI security in this Knowledge Base article.A firewall is blocking access to the remote computer.

Click here to start one. You should always try stopping and restarting the service before taking more drastic measures, such as rebuilding the WMI Repository.Restarting the WMI ServiceYou can restart the WMI service by typing the On the General tab, you should see information about the operating system and the version of WMI. What Is Wmi Error What’s WMIDiag?

If you want to designate a remote file share to store all the files created by WMIDiag, run WMIDiag with the LogFilePath parameter and specify the file path. The computer really doesn't exist The Windows Firewall is blocking the connection Connecting to Vista: netsh advfirewall firewall set rule group="windows management instrumentation (wmi)" new enable=yes Connecting to downlevel: Allow the As a Windows administrator, you’ve probably encountered errors reported by Windows Management Instrumentation (WMI). look at this web-site Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you!

Add comment Created on Nov 23, 2010 12:24:55 PM by Bruno Ruy (1) ●2 Permalink Votes:0 Your Vote: Up Down Hi, we also had this problem coming up and disappearing again. Wmi Remote Access Denied I found out these but I did check all of these: User account not admin - The user account is a local admin. What's weird is that nothing at all changed on the probe or the monitored machine. So this is not a PRTG implementation issue but purely some oddity with WMI.

Wmi Error Windows 7

Make sure the local time is correctly set on the client machine, the scanning machine and the domain controller. http://stackoverflow.com/questions/7557507/wmi-connection-error Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you! Wmi Error Fix For example, you might have applications that only update the Repository during installation; these applications do not have or use MOF files. Wmi Diagnosis Utility Can someone identify this biplane?

If it fails with error number 0x80041011, 0x80041012, or 0x80041085, then see the section of this document titled I’m getting an error regarding provider registration.I’m getting an error regarding provider registrationEven This sort of error can be especially frustrating because it’s so generic and offers no helpful hints about where to start investigating the problem. After downloading and installing Scriptomatic, start the utility and wait for the WMI namespace information to load. Why is that and what can I do about it? Wmi Error 10

Suppose the two versions of WMI are different. How can Malekith create the Aether? Fix all reported problems suggested by the WMI Diagnostic Tool Additional Resources: AskPerf Blog posts on WMI

Back totop Search this blog Search all blogs Top Server & Tools Blogs How do I remove the Pursuer's curse?

Thanks Add comment Created on Jan 15, 2015 9:29:51 AM by geordie (0) Permalink Votes:0 Your Vote: Up Down If nothing helps, even restarting the target and repairing the WMI on Wmi Error 0x80041003 Before you rebuild the Repository make sure you have tried the other remedies in this document; rebuilding the Repository should only be done as a last resort. Will the computer lock up?

For more information about troubleshooting problems with WMI scripts and the WMI service, see WMI Isn't Working!   WMI Diagnosis Utility The WMI diagnosis Utility (WMIDiag.exe) is no longer supported starting

For more information about WMI errors: The WMI logs track events from within the WMI core and from providers. How can tilting a N64 cartridge cause such subtle glitches? Give the user Remote Launch and Remote Activation permissions in dcomcnfg. Failed To Initialize All Required Wmi Classes Even if the account is in the Administrators group, UAC filtering means that a script runs as a standard user" share|improve this answer edited Jul 16 '14 at 21:05 answered Jul

I moved that WF1 device+sensors to the root probe (MON2) here in my home office and the device and all sensors worked via IP. The question still remained, which provider wasn’t registered properly? The service can be stopped; however, it is designed to automatically restart any time you connect to a WMI namespace using a tool (such as Wbemtest.exe) or a WMI script.Although unlikely, For more information, see Troubleshooting WMI Client Applications.

For example, to re-register the executable file Scrcons.exe type the following from the command prompt: Copy regsvr32 -s scrcons.exe After re-registering the .EXE files try your script again. For WMI problems that customers report to the Microsoft Global Escalation Services team, we’ve found that the root cause usually lies with an underlying dependency, such as DCOM settings, the registry, Meaning of "with a hose-pipe on him" C# Generics - How to avoid redundant method? Walk or "remote in" to the device that is not scanning properly.

At the end of the .LOG file you will find the WMI report which is the same information found in the .TXT file. The WMI SDK also has additional information about connecting to the WMI service through the Windows firewall.The version of WMI on your local computer is not compatible with the version of Is there any way to upgrade Windows 2000 so that it has the same classes, properties, and methods found on Windows XP? If the script does not work, that suggests a problem with the WMI service on the remote computer.

What should I do when the boss "pulls rank" to get their problems solved over our customers' problems? Die WMI Sensoren der beiden PCs lieferten nach dem Update auf 7.3.5 den oben beschriebenen WMI Fehler. Provider writers may also encounter debugging issues unless you are writing a decoupled provider. Use the information that appears in the dialog box when troubleshooting this problem: the dialog box will typically tell you the line of code where the error occurred (here, line 5)