Home > Wmi Error > Wmi Error Codes

Wmi Error Codes

Contents

Give the user Remote Launch and Remote Activation permissions in dcomcnfg. Loading... Failure to create an instance of or inherit from the __Win32Provider class to create the provider registration in the MOF file. WBEM_E_PROVIDER_LOAD_FAILURE 2147749907 (0x80041013) COM cannot locate a provider referenced For example, cd C:\Program Files\Microsoft SQL Server\MSAS10.MSSQLSERVER\OLAP\bin\Counters Run the following commands to unload and load counters: For unamed instances, run: unlodctr MSSQLServerOLAPService then lodctr perf-MSSQLServerOLAPServicemsmdctr.ini For named instances, run: unlodctr http://pdctoday.com/wmi-error/wmi-error-codes-list.php

Note  The following documentation is targeted for developers and IT administrators. On the target computer: 1) Open the Group Policy Object Editor (gpedit.msc), open Computer Configuration | Administrative Templates | Network | Network Connections | Windows Firewall 2) Open either Domain Profile For more information, see Debugging Providers. See http://www.microsoft.com/downloads/details.aspx?familyid=7ff99683-b7ec-4da6-92ab-793193604ba4&displaylang=en for information.

What Is Wmi Error

These codes may be returned by scripts, C++ applications, or Wmic. ALL RIGHTS RESERVED. How can I restore default trustees to Windows XP SP3, to make WMI happy? The problem is that I added the new property "Device Type" for my site criteria.

  1. This can be caused by low memory availability or excessive memory consumption by WMI. WBEM_E_TRANSACTION_CONFLICT 2147749997 (0x8004106D) Operation resulted in a transaction conflict. WBEM_E_FORCED_ROLLBACK 2147749998 (0x8004106E) Transaction forced a
  2. Loading...
  3. A WMI infrastructure problem, such as incorrect CIM or DCOM registration. 0x8007xxxx Errors originating in the core operating system.
  4. It should be #pragma DeleteInstance("instancepath", FAIL|NOFAIL) WBEMMOF_E_INVALID_QUALIFIER_SYNTAX 2147762221 (0x8004402D) The qualifier syntax is not valid.
  5. Specifying a port range for WMI is recommended for this type of environment.

Please refer to the help center for possible explanations why a question might be removed. Unknown Exception from IWbemClassObject::Get Try a Google Search Try searching for similar questions Browse our recent questions Browse our popular tags If you feel something is missing that should be here, Would it be inappropriate to use my workplace's postage machine to mail my tax returns? Wmi Return Codes MicrosoftTekniset 73,383 views 1:06:39 Abusing Windows Management Instrumentation (WMI) - Duration: 50:01.

If an error occurs, WMI returns one of the following error codes as a 32-bit value where the two high-order bits indicate the severity code of the message. 0 Success 1 This documentation is archived and is not being maintained. Note that due to the timing and nature of the asynchronous operation, the operation may not have been truly canceled. WBEM_E_SHUTTING_DOWN 2147749939 (0x80041033) User has requested an operation while WMI Exception from HRESULT: 0x800706BA Spotlight on SQL Server is not able to establish a connection with the target computer.

We appreciate your feedback. Wmi Error Fix Close Yeah, keep it Undo Close This video is unavailable. Run the following command: wmiadap /f Unregister and re-register the WMI classes. Haig Dickson 6,197 views 11:10 Windows Debugging and Troubleshooting - Duration: 1:06:39.

Wmi Error 10

I have been using the relevance - not exists WMI | True This statement works in the fixlet debugger, but machines that should be relevantare not for a WMI repair fixlet. Report the error to Microsoft Technical Support. WBEM_E_INVALID_STREAM 2147749899 (0x8004100B) One or more network packets were corrupted during a remote session. WBEM_E_NOT_SUPPORTED 2147749900 (0x8004100C) Feature or operation is not What Is Wmi Error Player claims their wizard character knows everything (from books). Wmi Error Windows 7 http://www.microsoft.com/downloads/details.aspx?displaylang=en&familyid=7FF99683-B7EC-4DA6-92AB-793193604BA4 Note: A reboot of the target machine is required.

Advisor professor asks for my dissertation research source-code more hot questions question feed lang-vb about us tour help blog chat data legal privacy policy work here advertising info mobile contact us Right-click My Computer-> Properties. See ASP.NET Ajax CDN Terms of Use – http://www.asp.net/ajaxlibrary/CDN.ashx. ]]> WebTrends view model not available or IncludeLegacyWebTrendsScriptInGlobal feature flag is off]]> Developer Network Developer Network Developer Sign in MSDN subscriptions Topic Forum Directory >‎ BigFix >‎ Forum: Fixlet Authoring >‎ Topic: WMI error codesThis topic has been locked. 5 replies Latest Post - ‏2014-07-19T00:44:42Z by MBARTOSH Display:ConversationsBy Date 1-6 of 6 Wmi Error 0x80041003

For example, cd C:\Program Files\Microsoft SQL Server\MSAS10.MSSQLSERVER\OLAP\bin\Counters Run the following commands to unload and load counters: unamed instances unlodctr MSSQLServerOLAPService lodctr perf-MSSQLServerOLAPServicemsmdctr.ini named instances unlodctr MSOLAP$Your_SSAS_NamedInstanceName lodctr perf-Your_SSAS_NamedInstanceNamemsmdctr.ini Tip: Replace Your_SSAS_NamedInstanceName Run the following command to parse all the performance libraries on the system and refresh the performance counter classes on the problematic machine: wmiadap /f Use wbemtest.exe to verify the WMI Since "Device Type" uses WMI, machines with broken WMI never evaluate correctly and therefore never get into the site where the WMI repairfixlet is. For example, myprog.exe /regserver. WBEM_E_INITIALIZATION_FAILURE 2147749908 (0x80041014) Component, such as a provider, failed to initialize for internal reasons. WBEM_E_TRANSPORT_FAILURE 2147749909 (0x80041015) Networking error that prevents normal operation has occurred.

To obtain more information about the source of the problem, you can download and run the WMI Diagnosis Utility diagnostic command line tool. Wmi Return Value 9 Error 0x800706BA The RPC server is unavailable. Failures can originate in other parts of the operating system and emerge as errors through WMI.

c:\test\test.vbs(16, 1) (null): 0x80041017 Running that query through wbemtest gives the description "Invalid query", even though the same query runs on other servers.

If you need to check the named instance name, use services.msc. Logging and Tracing The WMI log files no longer exist; they were replaced by Event Tracing for Windows (ETW). Verity that "Windows Management Instrumentation" is running and set to auto start after restart. Wmi Error 63 Your installation path may be different.

MAPToolkit 21,432 views 2:47 Windows PowerShell 2.0 for Beginners Training & Overview - EPC Group - Duration: 1:18:32. This constant is returned when a client creates an enumeration object, but does not retrieve objects from the enumerator in a timely fashion, causing the enumerator's object caches to back up. In-process provider was not registered using the regsvr32 command. Category Science & Technology License Standard YouTube License Show more Show less Loading...

wmic /node: 'MonHostFQDN' /user: 'DOMAIN\USER' path Win32_PerfRawData_PerfDisk_LogicalDisk get FreeMegabytes Rate this article (Rated 0 by 0visitors) English Chinese (中文) Chinese - Taiwan (文言) Czech (Čeština) Danish (Dansk) Dutch (Nederlands) English Possible to access WMI through ADO? Solution Recreate the WMI classes using: wmiadap.exe /f See http://msdn.microsoft.com/en-us/library/aa394528(VS.85).aspx for more information. References to other servers are not allowed. WBEMMOF_E_OUT_OF_RANGE 2147762205 (0x8004401D) Value out of range. WBEMMOF_E_INVALID_FILE 2147762206 (0x8004401E) The file is not a valid text MOF file or binary MOF

This is the accepted answer. For more information, see Registering a Provider. Learning resources Microsoft Virtual Academy Channel 9 MSDN Magazine Community Forums Blogs Codeplex Support Self support Programs BizSpark (for startups) Microsoft Imagine (for students) United States (English) Newsletter Privacy & cookies Verify correct host name or IP address (Configure | Connections).

Rate this article (Rated 0 by 0visitors) English Chinese (中文) Chinese - Taiwan (文言) Czech (Čeština) Danish (Dansk) Dutch (Nederlands) English French (Français) German (Deutsch) Italian (Italiano) Japanese (日本語) Korean (한국어) See Windows Account Permissions for more information. TheChennaiTV 675 views 1:36 Windows Repair (All In One) Free Windows Repair Tool - Duration: 11:10. Error Solution The RPC server is unavailable.

Here are some similar questions that might be relevant: Debugging (Tracing) WMI queries? The report also aids Microsoft support services in assisting you. Sign in Statistics 53,994 views 20 Like this video? Under any circumstances, do not delete the WMI repository as a first action because deleting the repository can cause damage to the system or to installed applications.

Providers also have debugging options and troubleshooting classes available. Typically, DCOM errors occur when connecting to a remote computer with a different operating system version. The provider can refire the event. WBEM_E_INVALID_FLAVOR 2147749958 (0x80041046) Specified qualifier flavor was not valid. WBEM_E_CIRCULAR_REFERENCE 2147749959 (0x80041047) Attempt was made to create a reference that is circular (for You can download the WMI Diagnosis Utility at the Download Center.

Specifying a port range for WMI is recommended for this type of environment.