A specific WMI operation failed because of An error in the request, for example, a WQL query fails or the account does not have the correct permissions. It is possible that the class definitions currently in the Repository have somehow become corrupted; in that case, recompiling your .MOF files will cause those class definitions to be overwritten and You can then use either the Scriptomatic or Wbemtest.exe to verify the actual property name.You might also encounter this problem when working with computers running different versions of Windows. If you are attempting to resolve a WMI error message on your home system, please refer to the Microsoft Support website.   WBEM_MC_REPOSITORY_INCONSISTENT 1073747424 (0x400015E0) The Windows Management Instrumentation Service detected get redirected here

This can be caused by a corruption in the repository files, security settings on this directory, lack of disk space, or other system resource issues such as lack of memory. WMI Diagnosis Utility TOC Collapse the table of content Expand the table of content This documentation is archived and is not being maintained. An alias in the form "$name" must follow the "as" keyword. WBEMMOF_E_CIMTYPE_QUALIFIER 2147762202 (0x8004401A) "CIMTYPE" qualifier cannot be specified directly in a MOF file. For example, to re-register the executable file Scrcons.exe type the following from the command prompt: Copy regsvr32 -s scrcons.exe After re-registering the .EXE files try your script again. https://msdn.microsoft.com/en-us/library/aa394559(v=vs.85).aspx

What Is Wmi Error

The WMI SDK also has additional information about connecting to the WMI service through the Windows firewall.The version of WMI on your local computer is not compatible with the version of Fortunately, you might be able to repair the Repository; the steps you need to take to do so depend on the version of Windows you are running.Important. This document (developed in conjunction with the WMI team at Microsoft) is designed to help you troubleshoot problems with WMI scripts and the WMI service.

  1. After downloading and installing Scriptomatic, start the utility and wait for the WMI namespace information to load.
  2. Learning resources Microsoft Virtual Academy Channel 9 MSDN Magazine Community Forums Blogs Codeplex Support Self support Programs BizSpark (for startups) Microsoft Imagine (for students) United States (English) Newsletter Privacy & cookies
  3. Failures can originate in other parts of the operating system and emerge as errors through WMI.
  4. This error usually applies to invalid attempts to delete classes or properties. WBEM_E_INVALID_QUERY 2147749911 (0x80041017) Query was not syntactically valid. WBEM_E_INVALID_QUERY_TYPE 2147749912 (0x80041018) Requested query language is not supported.

The topics in this document are listed roughly in order; for example, the last thing you should do is rebuild the entire Repository. You’ll be auto redirected in 1 second. Use the information that appears in the dialog box when troubleshooting this problem: the dialog box will typically tell you the line of code where the error occurred (here, line 5) Wmi Error Codes Under any circumstances, do not delete the WMI repository as a first action because deleting the repository can cause damage to the system or to installed applications.

As a result, it will automatically rebuild the Repository the next time it needs to access WMI information.Restart the WMI service (net start winmgmt) and try your script again.If your script Wmi Error 10 Unfortunately, no: there is no upgrade path for WMI.If the property name is correct but your script still fails, see the next section of this document: I’ve verified that the namespace, For more information, see Troubleshooting WMI Client Applications. This documentation is archived and is not being maintained.

Dev centers Windows Office Visual Studio Microsoft Azure More... Wmi Error Fix Open a command window and use the cd command to change to the %windir%\System32\Wbem directory. If the Repository becomes corrupted then the WMI service will not be able to function correctly. File it.

Wmi Error 10

WMI repository corruption may masquerade as classes or instances "not found". https://msdn.microsoft.com/en-us/library/aa394574(v=vs.85).aspx This constant is returned when an object must be committed and retrieved to see the property value. WBEM_E_NO_SCHEMA 2147750019 (0x80041083) Operation cannot be completed; no schema is available. WBEM_E_PROVIDER_ALREADY_REGISTERED What Is Wmi Error This is not the case when connecting to a remote computer: in order to use WMI remotely, you must have local Administrator rights on the remote machine. Wmi Error Windows 7 You can check the definition of these types of error codes by using the net helpmsg command in the command prompt window.

For example, the root\RSOP namespace can be found on Windows XP and Windows Server 2003, but not on Windows 2000; that means this script will fail on a machine running Windows Will the computer lock up? We appreciate your feedback. Windows Management Instrumentation WMI Reference WMI Infrastructure Objects and Values WMI Infrastructure Objects and Values WMI Return Codes WMI Return Codes WMI Return Codes WMI Data Types WMI Enumerations MOF Data Wmi Error 0x80041003

Well, consider the following script, which returns the name of each tape drive installed on a computer: Copy strComputer = "." Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2") Set colItems WMI Isn't Working! Is there a lesson in that for script writers? useful reference You’ll be auto redirected in 1 second.

An access denied error is returned by DCOM security when a low-integrity client tries to access WMI. Wmi Error Invalid Class In that case, you might try this script, which attempts to bind to the Win32_Process class: Copy strComputer = "." Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2:Win32_Process") If this script Before doing so you should enable WMI’s verbose logging option.

This tool produces a report that can usually isolate the source of the problem and provide instructions on how to fix it.

Is there any way to upgrade Windows 2000 so that it has the same classes, properties, and methods found on Windows XP? Unfortunately, not all versions of WMI are created equal. Provider writers may also encounter debugging issues unless you are writing a decoupled provider. Wmi Error 63 This can include a query that is too complex, retrieving an instance, creating or updating a class, deleting a class, or enumerating a class. WBEM_E_CLASS_HAS_CHILDREN 2147749925 (0x80041025) Attempt was made

Craig has been lecturing and doing research in the areas of WMI, network management, and distributed systems for the past three years. In that case, you might try this script, which attempts to bind to the root\default namespace: Copy strComputer = "." Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\default") If this script Under COM Security, click "Edit Limits" for both sections. Prior to this, he was a senior Windows project leader in research and development at SDX Business Systems, a subsidiary of Lucent Technologies.

From there type the following: Copy for %i in (*.mof, *.mfl) do Mofcomp %i If you use a script or batch file to recompile .MOF files or if you manually call In that case, try stopping and restarting the WMI service (see I’ve verified that the namespace, class, and property names are correct, yet my script still doesn’t work) and then proceed A WMI infrastructure problem, such as incorrect CIM or DCOM registration. 0x8007xxxx Errors originating in the core operating system. The one drawback to this approach: it’s not always obvious which .DLL files are associated with a particular namespace.To begin with, you must re-register all the .DLL files found in the

With this setup you will not be able to connect to a remote computer running Windows Server 2003. In that case, try stopping and restarting the WMI service (see I’ve verified that the namespace, class, and property names are correct, yet my script still doesn’t work) and then proceed The user does not have remote access to the computer through DCOM. WMI Reference WMI Infrastructure Objects and Values WMI Return Codes WMI Return Codes WMI Non-Error Constants WMI Non-Error Constants WMI Non-Error Constants WMI Error Constants WMI Non-Error Constants TOC Collapse the

Differences in the operating system and differences in installed applications and hardware often explain why a script runs fine on Computer A yet fails with an Invalid Namespace error on Computer If one of these applications is responsible for the problem with the WMI service (an admittedly difficult problem to diagnose) the only way to correct the class definitions in the Repository Learning resources Microsoft Virtual Academy Channel 9 MSDN Magazine Community Forums Blogs Codeplex Support Self support Programs BizSpark (for startups) Microsoft Imagine (for students) United States (English) Newsletter Privacy & cookies For example, this script removes the Where clause and simply reports back the Name and State for each service installed on a computer: Copy strComputer = "." Set objWMIService = GetObject("winmgmts:\\"

If you have a script that doesn’t work it’s usually due to a problem with the script and not due to a problem with WMI. See ASP.NET Ajax CDN Terms of Use – http://www.asp.net/ajaxlibrary/CDN.ashx. ]]> Developer Network Developer Network Developer Sign in MSDN subscriptions To enable verbose logging using the WMI control, do the following:Open the Computer Management MMC snap-in and expand Services and Applications.Right-click WMI Control and click Properties.In the WMI Control Properties dialog If you are an end-user that has experienced an error message concerning WMI, you should go to Microsoft Support and search for the error code you see on the error message.

For example, you try to connect to a class named Win32_Services (with an s on the end) when the actual class name is Win32_Service (without an s on the end).You reference For example, the command net helpmsg 64 returns the message: The specified network name is no longer available.   In C++, you can call FormatMessage and specify C:\Windows\System32\wbem\wmiutils.dll as the message This value is also returned when this method is called with a value of 0 for the uCount parameter. WBEM_S_ALREADY_EXISTS 262145 (0x40001) An attempt was made to create an object